[admin@-RB2011-CPE01] > interface ethernet monitor sfp1
name: sfp1
status: link-ok
auto-negotiation: done
rate: 1Gbps
full-duplex: yes
tx-flow-control: no
rx-flow-control: no
advertising:
link-partner-advertising:
sfp-module-present: yes
sfp-rx-loss: no
sfp-type: SFP-or-SFP+
sfp-connector-type: LC
sfp-link-length-9um: 40000m
sfp-vendor-name: OEM
sfp-vendor-part-number: GLC-BX-D
sfp-vendor-revision: A0
sfp-vendor-serial: B168025340104
sfp-manufacturing-date: 16-08-01
sfp-wavelength: 1550nm
sfp-temperature: 72C
sfp-supply-voltage: 3.281V
sfp-tx-bias-current: 16mA
sfp-tx-power: -2.992dBm
sfp-rx-power: -7.495dBm
eeprom-checksum: good
eeprom: 0000: 03 04 07 00 00 00 00 00 00 00 00 01 0d 00 28 ff ........ ......(.
0010: 00 00 00 00 4f 45 4d 20 20 20 20 20 20 20 20 20 ....OEM
0020: 20 20 20 20 00 00 00 00 47 4c 43 2d 42 58 2d 44 .... GLC-BX-D
0030: 20 20 20 20 20 20 20 20 41 30 20 20 06 0e 00 97 A0 ....
0040: 00 1a 00 00 42 31 36 38 30 32 35 33 34 30 31 30 ....B168 02534010
0050: 34 20 20 20 31 36 30 38 30 31 20 20 68 90 01 87 4 1608 01 h...
0060: 2e 00 08 05 3b 27 61 0f 5e 9f a5 18 68 78 3d 03 ....;'a. ^...hx=.
0070: f9 33 1f 00 00 00 00 00 00 00 00 00 e1 bc 29 af .3...... ......).
0080: 64 00 d8 00 5f 00 dd 00 8c a0 75 30 88 b8 79 18 d..._... ..u0..y.
0090: 9c 40 01 f4 88 b8 03 e8 7b 87 06 31 4d f1 09 d0 .@...... {..1M...
00a0: 27 10 00 0a 13 94 00 14 ff ff ff ff ff ff ff ff '....... ........
00b0: ff ff ff ff ff ff ff ff 00 00 00 00 00 00 00 00 ........ ........
00c0: 00 00 00 00 3f 80 00 00 00 00 00 00 01 00 00 00 ....?... ........
00d0: 01 00 00 00 01 00 00 00 01 00 00 00 ff ff ff 12 ........ ........
Treshold :
TX = -7 s/d -1 dBm